Engineering · Unit 3 · QCAA sample IA2 All sample IA2 questions
QCAA sample IA2 · Section 2 · Calculation

Question 26

[8 marks] Complex unfamiliar (est.)

Your teacher writes your IA2. This is the QCAA sample, so use it for the question shapes, and ask your teacher for practice that matches your school’s paper.

The question [8 marks]

A construction company is engineering a suspended concrete slab floor with plan dimensions of 10 m × 10 m and a thickness of 750 mm. The slab must be supported by four identical solid cylindrical concrete pillars, positioned at each corner.

Each pillar must safely support the applied load while minimising material usage. A factor of safety of 2 is required.

Using the concrete properties provided in the table, determine the required dimensions of each pillar so that, after the slab is poured and fully cured, the underside of the slab is positioned 3 m above ground level, within a tolerance of ±1 mm.

PropertyValueUnits
Ultimate tensile strength5MPa
Compressive strength32MPa
Young’s modulus25GPa
Density ($\rho$)2400kg/m³

Assume:

the slab load is shared equally by the four pillars

the pillars are solid cylinders

the self-weight of the pillars is negligible

the slab is poured only after the pillars have been formed and fully cured.

Watch the solution first

Follow the load down, size the pillar for strength, then for stiffness

The weight of the slab flows down into the pillars. Watch which row of the table sets the stress, how the stress fixes the cross-section, and what happens to the height of a pillar when the slab lands on it.

3 m when loaded10 m750 mm180 000 kg1764 kN441 kNcompressionm = 180 000 kgW = 1764 kNF = 441 kN per pillarPropertyValueUnitsUltimate tensile strength5MPaUltimate tensile strength5MPa✗Compressive strength32MPaYoung’s modulus25GPaDensity (ρ)2400kg/m³✓allowable stress = 32 ÷ 2 = 16 MPaε = 16 ÷ 25 000 = 0.00064cross-section of one pillar187.3 mmA = 27 562.5 mm²r = 93.7 mmd = 187.3 mmround up to 188 mmL = 3.0019 m3 mcast at L = 3.0019 mshortens about 1.9 mm to 3 m(shortening exaggerated)slab not poured yetMark 1Mark 2Mark 3Mark 4Mark 5Mark 6Mark 7Mark 8m = ρV = 2400 × (10 × 10 × 0.75) = 180 000 kgW = mg = 180 000 × 9.8 = 1 764 000 N = 1764 kNFour pillars share it equally: F = 1764 ÷ 4 = 441 kN eachThe pillars are squashed, so use the compressive strength, 32 MPa, not 5 MPaFactor of safety 2: allowable stress = 32 ÷ 2 = 16 MPaA = F ÷ σ = 441 000 ÷ 16 = 27 562.5 mm², so r = 93.7 mm and d = 187.3 mmE = 25 GPa = 25 000 MPa, so ε = σ ÷ E = 16 ÷ 25 000 = 0.00064Cast each pillar at L = 3 ÷ (1 − 0.00064) = 3.0019 m. The slab shortens it to 3 m.Each pillar: diameter 187.3 mm, so round up to 188 mm, and cast height 3.002 m

Compression is orange, with arrows pressing into the pillar. The width of the pillars and the shortening are not to scale.

Now for the engineering

Change the slab and the factor of safety, then test the tolerance

Set the factor of safety and the slab thickness, then choose the row of the table that sizes the pillars. The gauge shows where the underside of the slab ends up if a pillar is cast at exactly 3 m. Then try each slip to see what it does to the answer. The question is a factor of safety of 2 and a 750 mm slab.

Side view, to scale Cross-section of one pillar 10 m 3 m when loaded ? Choose a strength row 200 mm Cast at exactly 3 m: underside of the slab, in mm from 3 m ±1 mm −4−3−2−10+1
Which row of the table sizes the pillars?
Try a common slip

QCAA sample marking scheme · 8 marks

Work through the solution one mark at a time

Try each step yourself before you show it. The first six marks find the diameter from strength. The last two find the height from stiffness.

Step 1 · Mass of the slabMark 1

The slab is a rectangular block. Change 750 mm to 0.75 m so the volume comes out in cubic metres.

$$\begin{aligned}m&=\rho V\\&=2400\times(10\times10\times0.75)\\&=180\,000\text{ kg}\end{aligned}$$

Why?

Density is the mass of each cubic metre, so the mass is the density times the volume. Everything the pillars carry starts here.

Marker: calculates the mass of the concrete slab

Step 2 · Weight of the slabMark 2

Turn the mass into a force with $g=9.8\text{ m s}^{-2}$.

$$\begin{aligned}W&=mg\\&=180\,000\times9.8\\&=1\,764\,000\text{ N}\\&=1764\text{ kN}\end{aligned}$$

Why?

A mass is not a force. The pillars feel the weight of the slab, and a stress needs newtons.

Marker: calculates the weight force of the slab

Step 3 · Force on each pillarMark 3

The question says the slab load is shared equally by the four pillars.

$$\begin{aligned}F&=\frac{1764}{4}\\&=441\text{ kN per pillar}\end{aligned}$$

Why?

Each pillar is designed for its own share of the load. The question also says the self-weight of the pillars is negligible, so the slab is the only load.

Marker: calculates the force applied to each pillar

Step 4 · Which strengthMark 4

The pillars are being squashed, so the strength that matters is the compressive strength, 32 MPa. The 5 MPa tensile strength is in the table to see whether you choose correctly.

Why?

A slab sitting on top of a pillar pushes down on it. Nothing is pulling the pillar apart, so its tensile strength never comes into it. Always match the strength to the loading.

Marking

Allow FT marks

Marker: Identifies the load is compressive and interprets tabled data correctly

Step 5 · Allowable stressMark 5

Divide the strength by the factor of safety.

$$\begin{aligned}\text{allowable working stress}&=\frac{32}{2}\\&=16\text{ MPa}\end{aligned}$$

Why?

A factor of safety of 2 means the pillar is only ever asked for half of what the concrete can take.

Marking

Allow fos of 2 to be applied whenever relevant

Note

The sample marking scheme labels the 32 MPa compressive strength as a yield stress, because that is the word in the formula.

Marker: calculates allowable working stress

Step 6 · Minimum area and diameterMark 6

Working in newtons and millimetres:

$$\begin{aligned}A&=\frac{F}{\sigma}=\frac{441\,000}{16}=27\,562.5\text{ mm}^2\\r&=\sqrt{\frac{27\,562.5}{\pi}}=93.7\text{ mm}\\d&=187.3\text{ mm}\end{aligned}$$

Why?

The pillar must use as little material as it safely can, so it works at exactly the allowable stress. Newtons over square millimetres gives megapascals, so 441 kN goes in as 441 000 N.

Marking

Allow answer in radius or diameter.

Note

The sample marking scheme’s working reaches a radius of 0.0937 m and a diameter of 187 mm, but its closing sentence states 185.4 mm. The 185.4 mm is what you get from the area rounded down to 0.027 m². The 187 mm is the value its own working supports.

Marker: calculates minimum area and diameter of each pillar

Step 7 · Strain in each pillarMark 7

A pillar of exactly this diameter works at exactly 16 MPa. Young’s modulus is 25 GPa, which is 25 000 MPa.

$$\begin{aligned}\varepsilon&=\frac{\sigma}{E}\\&=\frac{16}{25\,000}\\&=0.00064\end{aligned}$$

Why?

The diameter comes from strength. The height comes from stiffness. A loaded pillar shortens, and the strain says by what fraction of its length.

Note

The sample marking scheme rounds the area to 0.027 m² when finding the strain and gets 0.00065, where 16 ÷ 25 000 is 0.00064. Both give a height of 3.002 m.

Marker: calculates the stain applied to each pillar

Step 8 · Cast heightMark 8

Let the pillar be cast at height $L$. It shortens to 3 m under the slab, so its change in length is $L-3$.

$$\begin{aligned}\varepsilon&=\frac{L-3}{L}=1-\frac{3}{L}\\L&=\frac{3}{1-0.00064}\\&=3.0019\text{ m}\end{aligned}$$

Why?

The slab is poured only after the pillars have cured, so the pillars are cast with no load on them and shorten afterwards. The tolerance is ±1 mm, so a pillar cast at exactly 3 m would leave the slab about 2 mm too low and fail the requirement. That is why the strain step is in the question.

Marking

Accept dimension in m and mm

Marker: calculates height required

Step 9 · The dimensionsNo mark on its own

“Dimensions” of a cylinder means two things, a diameter and a height. Each pillar is cast about 2 mm taller than 3 m, at 3.002 m, and squashes by that 2 mm when loaded.

Each pillar: minimum diameter 187.3 mm, so round up to 188 mm, and cast height 3.002 m.
Note

In practice you would round the diameter up, never down, since a thinner pillar would exceed the allowable stress. A minimum of 187.3 mm becomes 188 mm.

Common errors

If I had to guess where you might lose marks…

  • Using the 5 MPa tensile strength. You get an allowable stress of $5\div2=2.5$ MPa, an area of $441\,000\div2.5=176\,400\text{ mm}^2$ and a diameter of 473.9 mm instead of 187.3 mm. Mark 4 is lost. The pillars are squashed, so read the compressive row.
  • Leaving out the factor of safety. You divide by the full 32 MPa, so $A=441\,000\div32=13\,781.25\text{ mm}^2$ and $d=132.5$ mm. Mark 5 is lost, and the strain comes out at 0.00128, so the height is wrong as well.
  • Putting the whole slab on one pillar. You use 1764 kN instead of 441 kN, so $A=1\,764\,000\div16=110\,250\text{ mm}^2$ and $d=374.7$ mm, exactly double. Mark 3 is lost. There are four pillars and they share the load equally.
  • Using the mass as the force. You share 180 000 kg between the pillars and treat 45 000 as newtons, so $A=45\,000\div16=2812.5\text{ mm}^2$ and $d=59.8$ mm. Mark 2 is lost. Multiply by 9.8 before the mass goes anywhere near a stress.
  • Stopping at the diameter. A cylinder has two dimensions. A pillar cast at exactly 3 m shortens by $0.00064\times3000=1.92$ mm under the slab, which is outside the ±1 mm tolerance. Marks 7 and 8 are lost. Find the strain, then cast the pillar at 3.002 m.

Only mark this done when you could do it without help. Reading the solution does not count.

Back to the index

Question wording is from the QCAA Engineering 2025 v1.4 IA2 sample assessment instrument, and the marker lines are from its sample marking scheme, © State of Queensland (QCAA) 2026, licensed under CC BY 4.0. Figures are redrawn. The solutions, animations and commentary are Tangent Tuition’s. Tangent Tuition is not affiliated with the QCAA.